 tfs 80D2doc
Version 1.1
16.05.2000.
VI TELEFILTER
Filter Specification
TFS 80 D2 - 1/4
1. Measurement condition : Ambient temperature TA: Input power level: Terminating impedances in fc: 23 C 0 dBm. for input: for output:
50 - 56 pF 50 0 pF,
2. Characteristics
Remark: Reference level for the relative attenuation arel of the TFS 80 D2 is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The reference frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae.
Data Insertion loss (Reference level) Centre frequency Pass band (-3 dB) Bandwidth at ambient temperature: 3 10 20 36 45 dB - band width dB - band width dB - band width dB - band width dB - band width arel ... .... ... ... ... ... fc fc fc fc fc fc 100 - 200 + 400 500 1,0 35 kHz kHz kHz kHz MHz MHz ae
typ. value 14,0 dB 80,07 MHz
tolerance / limit max. 14,5 dB 80,07 0,01 MHz fC- 100 kHz ... fC + 100 kHz
fc at ambient temperature ( fCAT )
212 350 450 770 990
kHz kHz kHz kHz kHz
min. 200 kHz
max. 800 kHz max.1000 kHz
Relative attenuation fc - 400 fc + 200 fc 400 fc 500 fc 1,0 fc kHz kHz kHz kHz kHz
40 50...60 60...70
dB dB dB
max. min. min. min. min. min.
3 11 19 36 45 50
dB dB dB dB dB dB
Group delay ( mean value in PB ): Group delay ripple : fc - 100 kHz .....fc fc ... fc + 100 kHz Deviation from linear phase in PB (p-p): Triple transit attenuation compared to main signal Crosstalk Frequency inversion temperature ( To ) Temperature coefficient of frequency ( Tcf ) Frequency deviation of fc over temperature: * ) Operating temperature range Storage temperature range
4,12 s 500 ns 700 ns 5,2 33...34 dB 55...60 dB
max. 600 ns max. 750 ns
10 -0,045 ppm/K fc(Hz) = Tcf(ppm/K) x (T - To) x fTo (MHz) - 25 C ... + 75 C - 30 C ... + 85 C
* ) fTo is reference frequence fc at frequency inversion temperature (To )
Generated:
Dunzow W.
Checked/Approved:
Dr. Bert Wall
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs 80D2doc
Version 1.1
16.05.2000.
VI TELEFILTER
3. Package: 38,10 mm
Filter Specification
TFS 80 D2 - 2/4
TFS 80 D2 tft M20
25,4 mm
Datecode: K L M .... 5,0 Max 5,00,5
Year + week 1998 1999 2000
0,450,03 5,08 3,81
4
6
12 14 20,32
Pin 4 Pin 6 Pin 17 Pin 15 Pin 12,14,26,28
Input Input RF Return Output Output RF Return Package Ground
28 26 22,86 33,02
17 15
4. 50 matching network (to see Application Note 0f TFS 80D2):
4
6
12 14
L1
28 26
17 15
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs 80D2doc
Version 1.1
16.05.2000.
VI TELEFILTER 5 Soldering temperature conditions
Filter Specification
TFS 80 D2 - 3/4
Soldering temperature profile
Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C
Soldering temperature profile
260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240
Table for temperature vs. time during the soldering process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs 80D2doc
Version 1.1
16.05.2000.
VI TELEFILTER
History Version 1.0 Reason of Changes
Filter Specification
TFS 80 D2 - 4/4
Name
Date
Change filter specifications TFS 80D and TFS 80D1 according to customer requirements: 1. Change of insertion loss limit : from ILo = max. 16,0 dB without matching to ILo = max. 14,5 dB with matching . 2. Change of centre frequency tolerance from fc = 80,07 0,02 kHz to fc = 80,07 0,01 kHz . 3. Change of band width limit : from BW(-3dB) = min. 180 kHz without matching to BW(-3dB) = min. 200 kHz with matching; Change of selection from -34 dB up to -36 dB 4. in fc 400 kHz ... fc 500 kHz . 1. Change of selection limit line ( - 45 dB ) from fc 500 kHz ... fc 850 kHz to fc 500 kHz ... fc 1000 kHz Correction of frequency inversion temperature : from To = 20 to To = 10 (after measure ) and temperature coefficient of frequency : from Tcf = -0,055 ppm/K to Tcf = -0,045 ppm/K .
Dunzow W.
10.05.2000
1.1
Dunzow W.
16.05.2000
2.
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.


▲Up To Search▲   

 
Price & Availability of TFS80D2

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X